COMMERCIAL MARINE TYPE MNI MANUFACTURED BY BERKSHIRE ELECTRIC CABLE CO. LEEDS, MA, USA


BECCO Number

No. of
Cond

Conductor size AWG/
kcmils

Insulation Thickness Mils

Overall Jacket Thickness

Un-armored Outside Diameter

Aluminum Armored Outside Diameter

Un- Armored Weight

Aluminum Armored Weight

Ampacity 40 deg C Ambient Temp

Ampacity 50 deg C Ambient Temp

PVC/NYL

Mils

Inches

Lbs/1000 Ft.

Amps

Amps

MNI-7-3 7 15 15 5 45 0.390 .450 114 135 11 9
MNI-10-3 10 15 15 5 60 0.500 .550 159 185 8 7
MNI-14-3 14 15 15 5 60 0.560 .610 226 255 8 7
MNI-20-3 20 20 15 5 60 0.620 .670 295 327 8 7
MNI-24-3 24 30 15 5 80 0.720 .770 358 395 7 6
MNI-30-3 30 16 15 5 80 0.770 .820 431 470 7 6
MNI-37-3 37 16 15 5 80 NA * NA * 556 600 6 5
 
MNI-7-4 7 14 15 5 45 .440 .490 157 180 17 15
MNI-10-4 10 14 15 5 60 .580 .630 240 270 13 11
MNI-14-4 14 14 15 5 60 .630 .680 308 340 13 11
MNI-20-4 20 14 15 5 80 .710 .760 409 445 13 11
MNI-24-4 24 14 15 5 80 NA * NA * 494 535 11 10

NA * Armoring is not available on cable diameters greater than .800 inches.


APPLICATIONS

Type NI cables are designed for use on non U.S. Navy commercial marine vessels. These cables may be used on work board, tugs, fishing boats, casino boats, and other commercial vessels in addition to certain oil rig applications. These cables should be used for the distribution of power up to their voltage rating throughout the system, and may be used in lighting, communication, control, and electronic circuits as desired; suitable for installation in trays, troughs, channels conduit, and wireways. Finished cables pass the IEEE-383 and IEEE Standard 1202 flammability test.

IEEE STANDARD 45

USCG AND ABS ACCEPTED

UL (TYPE UBVZ MARINE SHIPBOARD CABLE) APPROVED