COMMERCIAL MARINE TYPE TP(AWG)TIU MANUFACTURED BY BERKSHIRE ELECTRIC CABLE CO. LEEDS, MA, USA


BECCO Number

Conductor size AWG/
kcmils

No.
of
Pairs

In
Thickness Insulation

Overall Jacket Thickness

Outside Diameter

Armored Outside Diameter

Un- Armored Weight

Aluminum Armored Weight

Mils

Mils

Inches

Lbs/1000 Ft.

TP20TIU-1 20 1 30 45 0.250 0.300 42 55
TP20TIU-2 20 2 30 45 0.413 0.460 75 99
TP20TIU-3 20 3 30 45 0.480 0.530 91 115
TP20TIU-5 20 5 30 60 0.550 0.600 155 184
TP20TIU-10 20 10 30 60 0.760 0.810 266 306
TP20TIU-15 20 15 30 80 0.910 NA * 405 NA *
TP20TIU-20 20 20 30 80

1.060

NA * 507 NA *
 
TP18TIU-1 18 1 30 45 0.290 0.340 47 63
TP18TIU-2 18 2 30 45 0.480 0.530 89 116
TP18TIU-3 18 3 30 60 0.510 0.560 135 164
TP18TIU-5 18 5 30 60 0.650 0.700 190 223
TP18TIU-10 18 10 30 80 0.950 NA * 373 NA *
TP18TIU-15 18 15 30 80 1.080 NA * 504 NA *
 
TP16TIU-1 16 1 30 45 0.310 0.360 57 75
TP16TIU-2 16 2 30 45 0.520 0.570 122 151
TP16TIU-3 16 3 30 60 0.590 0.640 154 185
TP16TIU-5 16 5 30 60 0.700 0.750 218 253
TP16TIU-10 16 10 30 80 1.020 NA * 424 NA *
TP16TIU-15 16 15 30 80 1.170 NA * 576 NA *
TP16TIU-20 16 20 30 80 1.300 NA * 729 NA *

NA * Armoring is not available on cable diameters greater than .800 inches.


APPLICATIONS

Type NI cables are designed for use on non U.S. Navy commercial marine vessels. These cables may be used on work board, tugs, fishing boats, casino boats, and other commercial vessels in addition to certain oil rig applications. These cables should be used for the distribution of power up to their voltage rating throughout the system, and may be used in lighting, communication, control, and electronic circuits as desired; suitable for installation in trays, troughs, channels conduit, and wireways. Finished cables pass the IEEE-383 and IEEE Standard 1202 flammability test.

IEEE STANDARD 45

USCG AND ABS ACCEPTED

UL (TYPE UBVZ MARINE SHIPBOARD CABLE) APPROVED